Power supply: 12V DC
Rated switching current:
- max 10A 230V AC
- max 10A 14V DC
Timing range:
- 0-999sec
- 0-999min
- 0-999hour
Mode types:
- Delay
- Timing
- Loop
To a mode, press and hold the "SET" button for 10 seconds
Exiting the mode is done automaticy after 10 seconds of inactivity
Setting modes:
Mode 0: Relay energizes after T1 delay time (T1 timing)
Mode 1: Relay releases after T1 delay time (T1 timing)
Mode 2: After a T1 delay time, the relay energizes (T1 timer) and after a T2 delay time, the relay releases (T2 timer)
Mode 3: Relay releases after T1 delay time (T1 timing) and relay releases after T2 delay time (T2 timing)
Mode 4: After a T1 delay time, the relay energizes (T1 timer), after a T2 delay time, the relay releases (T2 timer) and repeats the cycle.
Mode 5: After a T1 delay time, the relay releases (T1 timer), after a T2 delay time, the relay energizes (T2 timer) and repeats the cycle.
Dimensions: 48x39x33mm
Instation dimensions: 45.5x26mm